LG Electronics LP153HD3B Guide d'installation

Naviguer en ligne ou télécharger Guide d'installation pour Filtres à air LG Electronics LP153HD3B. LG Electronics LP153HD3B Installation Guide Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 8
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Installation 56
2.4 Installation of unit
Installation of unit6RWU0-03A
PTAC
I
N
D
O
O
R
Outdoor Grille
Wall Sleeve
Unit
Front Grille
(Shipped with the unit)
1 1
1
1
1
1
1
1
1
1
1
3 1
14
14
14
4
1
2
5
6
7
7
8
10
11
9
12
13
The PTAC and its components are as shown below.
1. WALL SLEEVE
2. FRONT GRILLE
3. AIR FILTER
4. AIR INTAKE
5. AIR DISCHARGE
6. VERTICAL AIR DEFLECTOR
(HORIZONTAL LOUVER)
7. EVAPORATOR
8. CONTROL PANEL
9. POWER CORD
10. COMPRESSOR
11. BASE PAN
12. BRACE
13. CONDENSER
14. OUTDOOR GRILLE (ARCHITEC-
TURAL GRILLE)
Use the correct wall sleeve and outdoor grille
This unit is designed to be installed in the insulated wall sleeve.
When you place the unit into the existing sleeve, the wall sleeve
used to mount the new unit must be in good structural condition
and have the outdoor grille that securely attaches to the sleeve
or the flange of the sleeve to secure the new air conditioner.
With the LG sleeve, you can maintain the best performance of
the new air conditioner.
If you keep the existing sleeve, you run the risk of poor perfor-
mance or product failure. This is not covered
under the LG warranty.
Remove the vertical deflectors in the existing grille to reduce
condenser air recirculation that can cause the unit to poor cool-
ing or heating and component failure.
Vue de la page 0
1 2 3 4 5 6 7 8

Résumé du contenu

Page 1 - 2.4 Installation of unit

Installation 562.4 Installation of unit Installation of unit6RWU0-03APTACINDOOROutdoor GrilleWall SleeveUnitFront Grille(Shipped with the unit)1 1111

Page 3 - 2.5 WALL SLEEVE INSTALLATION

Installation 58Installation of unit6RWU0-03APTAC2.5 WALL SLEEVE INSTALLATIONWall Case Installation DataGeneral Generally, units are installed 3"

Page 5 - Installation of unit6RWU0-03A

Installation 60Installation of unit6RWU0-03APTAC

Page 6 - 61 Installation

61 Installation Installation of unit 6RWU0-03APTACWALL SECTION – DETAILED SIDE VIEWFRAME AND BRICK VENEER INSTALLATIONCord Set ConnectedCAULK*Sub-Base

Page 7 - • unit installation

Installation 62Installation of unit6RWU0-03APTAC• unit installation1. Remove the shipping screw from the ventilation door.2. Remove the front gille b

Page 8 - ELECTRICAL SAFETY

63 Installation Installation of unit 6RWU0-03APTACPREFERRED METHODEnsure proper groundexists before useUse Wall Receptacle Power SupplyStandard 208/23